Catalog
10800 Middle Ave., Bldg B.
Elyria, Ohio 44035
Phone: (440)327-5050
Fax: (440) 458-8140

sales@ltipowersystems.com

Home
History
Catalog
Support
Specifications
Service

Three Phase Output UPS
Single/Three Phase Output Inverters
Single Phase Output Series 1000 UPS
Single Phase Output Series 1000 Inverters
Single Phase Output LT 500 Series UPS
Single Phase Static Transfer Switch
Modification of Standard Products
3 Phase Input 1 Phase Output
Frequency Converters
LTI true On-line double conversion design goes far beyond merely providing protection during untimely power outages. Our carefully engineered design will extend equipment life and reduce costly hardware failures.

By continually supplying your critical load with near perfect AC Power, we prevent damaging power line abnormalities from ever reaching your sensitive equipment.

Our custom built UPS and inverters are available in a wide variety of power ratings, configurations and designs to meet the requirements of your installation.

ProUPS 3 Phase Family of 10 to 60KVA UPS using a 120VDC Battery Link and consisting of 24 standard configurations:

The ProUPS series of on-line UPS operate continuously, regardless of what happens to the commercial AC power source. Reliable circuit design combined with extensive protection against abnormal operating conditions such as overload, short circuit, overheating etc. has resulted in an exceptionally reliable UPS or Backup Power System.
Description
Part #
Model
10 KVA / 8 KW 3Ph 208 In 208 Out
5182-010
LT102020H
10 KVA / 8 KW 3Ph 480 In 208 Out
5182-011
LT104820H
10 KVA / 8 KW 3Ph 480 In 480 Out
5182-012
LT104848H
15 KVA / 12 KW 3Ph 208 In 208 Out
5182-015
LT152020H
15 KVA / 12 KW 3Ph 480 In 208 Out
5182-016
15 KVA / 12 KW 3Ph 480 In 480 Out
5182-017
LT154848H
20 KVA / 16 KW 3Ph 208 In 208 Out
5182-020
LT202020H
20 KVA / 16 KW 3Ph 480 In 208 Out
5182-021
LT204820H
20 KVA / 16 KW 3Ph 480 In 480 Out
5182-022
25 KVA / 20 KW 3Ph 208 In 208 Out
5182-025
LT252020H
25 KVA / 20 KW 3Ph 480 In 208 Out
5182-026
LT254820H
25 KVA / 20 KW 3Ph 480 In 480 Out
5182-027
LT254848H
30 KVA / 24 KW 3Ph 208 In 208 Out
5182-030
30 KVA / 24 KW 3Ph 480 In 208 Out
5182-031
30 KVA / 24 KW 3Ph 480 In 480 Out
5182-032
LT304848H
40 KVA / 32 KW 3Ph 208 In 208 Out
5182-040
LT402020H
40 KVA / 32 KW 3Ph 480 In 208 Out
5182-041
40 KVA / 32 KW 3Ph 480 In 480 Out
5182-042
LT404848H
50 KVA / 40 KW 3Ph 208 In 208 Out
5182-050
LT502020H
50 KVA / 40 KW 3Ph 480 In 208 Out
5182-051
LT504820H
50 KVA / 40 KW 3Ph 480 In 480 Out
5182-052
LT504848H
60 KVA / 50 KW 3Ph 208 In 208 Out
5182-060
LT602020H
60 KVA / 50 KW 3Ph 480 In 208 Out
5182-061
LT604820H
60 KVA / 50 KW 3Ph 480 In 480 Out
5182-062
LT604848H
 
3 Phase ProUPS 10KVA Cabinet
3 Phase ProUPS 15 to 60KVA Cabinet
Top of Page

ProUPS 3 Phase Family of 10 to 150KVA UPS using a 360VDC Battery Link and consisting of 36 standard configurations:

The ProUPS series of on-line UPS operate continuously, regardless of what happens to the commercial AC power source. Reliable circuit design combined with extensive protection against abnormal operating conditions such as overload, short circuit, overheating etc. has resulted in an exceptionally reliable UPS or Backup Power System.
Description
Part #
Model
10 KVA / 8 KW 3Ph 208 In 208 Out
5183-010
10 KVA / 8 KW 3Ph 480 In 208 Out
5183-011
10 KVA / 8 KW 3Ph 480 In 480 Out
5184-012
15 KVA / 12 KW 3Ph 208 In 208 Out
5183-015
15 KVA / 12 KW 3Ph 480 In 208 Out
5183-016
15 KVA / 12 KW 3Ph 480 In 480 Out
5184-017
20 KVA / 16 KW 3Ph 208 In 208 Out
5183-020
20 KVA / 16 KW 3Ph 480 In 208 Out
5183-021
20 KVA / 16 KW 3Ph 480 In 480 Out
5184-022
25 KVA / 20 KW 3Ph 208 In 208 Out
5183-025
LT252020
25 KVA / 20 KW 3Ph 480 In 208 Out
5183-026
LT254820
25 KVA / 20 KW 3Ph 480 In 480 Out
5184-027
30 KVA / 24 KW 3Ph 208 In 208 Out
5183-030
30 KVA / 24 KW 3Ph 480 In 208 Out
5183-031
30 KVA / 24 KW 3Ph 480 In 480 Out
5184-032
40 KVA / 32 KW 3Ph 208 In 208 Out
5183-040
40 KVA / 32 KW 3Ph 480 In 208 Out
5183-041
40 KVA / 32 KW 3Ph 480 In 480 Out
5184-042
50 KVA / 40 KW 3Ph 208 In 208 Out
5183-050
50 KVA / 40 KW 3Ph 480 In 208 Out
5183-051
50 KVA / 40 KW 3Ph 480 In 480 Out
5184-052
60 KVA / 50 KW 3Ph 208 In 208 Out
5183-060
LT602020
60 KVA / 50 KW 3Ph 480 In 208 Out
5183-061
60 KVA / 50 KW 3Ph 480 In 480 Out
5184-062
LT604848
80 KVA / 64 KW 3Ph 208 In 208 Out
5183-080
80 KVA / 64 KW 3Ph 480 In 208 Out
5183-081
LT804820
80 KVA / 64 KW 3Ph 480 In 480 Out
5184-082
100 KVA / 80 KW 3Ph 208 In 208 Out
5183-100
LT1002020
100 KVA / 80 KW 3Ph 480 In 208 Out
5183-101
LT1004820
100 KVA / 80 KW 3Ph 480 In 480 Out
5184-102
LT1004848
120 KVA / 100 KW 3Ph 208 In 208 Out
5183-120
LT1202020
120 KVA / 100 KW 3Ph 480 In 208 Out
5183-121
LT1204820
120 KVA / 100 KW 3Ph 480 In 480 Out
5184-122
LT1204848
150 KVA / 120 KW 3Ph 208 In 208 Out
5183-150
LT1502020
150 KVA / 120 KW 3Ph 480 In 208 Out
5183-151
LT1504820
150 KVA / 120 KW 3Ph 480 In 480 Out
5184-152
LT1504848
3 Phase ProUPS 10-40KVA Cabinet
3 Phase ProUPS 50-80KVA
Top of Page
3 Phase ProUPS 100-150KVA

ProUPS Family of 200 to 300KVA UPS using a 480VDC Battery Link and consisting of 5 standard configurations:

The ProUPS series of on-line UPS operate continuously, regardless of what happens to the commercial AC power source. Reliable circuit design combined with extensive protection against abnormal operating conditions such as overload, short circuit, overheating etc. has resulted in an exceptionally reliable UPS or Backup Power System.
Description
Part #
Model
200 KVA / 160 KW 3Ph 208 In 208 Out
5183-200
LT2002020
200 KVA / 160 KW 3Ph 480 In 208 Out
5183-201
LT2004820
200 KVA / 160 KW 3Ph 480 In 480 Out
5184-202
250 KVA / 200 KW 3Ph 480 In 480 Out
5184-252
LT2504848
300 KVA / 240 KW 3Ph 480 In 480 Out
5184-302
LT3004848
3 Phase ProUPS 200-300KVA
Top of Page
ProUPS 125VDC Inverters from 10 to 60KVA offered in both 50Hz and 60Hz Models:

The LTI 125VDC inverter line is designed for industrial applications as well as office use. The LTI inverter converts the DC input source into clean, reliable, uninterruptible AC power. The wide DC input acceptance range of 105vdc to 150vdc allows operation from different types of DC power plants. The inverter comes standard with a true solid state Static Transfer Switch, front panel monitoring and controls.

True On-Line Technology for Maximum Power Protection
Available in 10, 15, 20, 30, 40, 50, and 60KVA Power Ratings
Single or Three Phase Outputs
50Hz and 60Hz Models
20-Year Expected Design Life
Solid State Static Transfer Switch Standard
Copper Wound Transformers
LCD Monitoring Panel
LED Power Flow Diagram
RS232 Communications Port
Form "C" Interlaced Contacts
Light Gray Powder Coat Finish
Monitoring Software
Meets UL1778, NEMA, NEC, ANSI, and FCC Requirements
 
ProUPS 10-60KVA Inverter
Top of Page
Series 1000 Single Phase Family of UPS from 3.75 to 10KVA using a 120VDC Battery Link and consisting of 16 standard configurations.
No Uninterruptible Power Supply delivers cleaner output power than the LTI Power Systems Series 1000. Total input to output Isolation. LTI Power Systems Double Conversion, On-Line UPS converts the contaminated incoming power into a regulated and filtered direct current (DC). The DC charges the batteries and is reconstructed into a new isolated and clean alternating current (AC). This pure AC
is continuously supplied to your critical load, extending its life by providing protection against brownouts, blackouts, and even lightning strikes.

Each model from within the family has a variety of Input and Output voltages and frequencies to choose from as well as internal or external batteries. Other options include: Internal or external wall mounted bypass switch, Separate bypass input, Digital meter panels, Frequency meters, Surge suppression, Alarm extension, and built-in Output Distribution panels.

Series 1000 UPS with or without Internal Battery
Description
Part #
Model
3.75 KVA / 3.0 KW 60HZ 120VDC 1Ph In/Out with Bat
5196-330A
3.75 KVA / 3.0 KW 60HZ 120VDC 1Ph In/Out less Bat
5196-330A WOB
3.00 KVA / 3.0KW 50HZ 120VDC 1Ph In/Out with Bat
5195-330A
LT1030
3.00 KVA / 3.0KW 50HZ 120VDC 1Ph In/Out less Bat
5195-330A WOB
LT1030
6.25 KVA / 5.0KW 60HZ 120VDC 1Ph In/Out with Bat
5196-350
6.25 KVA / 5.0KW 60HZ 120VDC 1Ph In/Out less Bat
5196-350 WOB
5.00 KVA / 5.0KW 50HZ 120VDC 1Ph In/Out with Bat
5195-350
LT1050
5.00 KVA / 5.0KW 50HZ 120VDC 1Ph In/Out less Bat
5195-350 WOB
LT1050
9.375 KVA / 7.5KW 60HZ 120VDC 1Ph In/Out with Bat
5196-375
9.375 KVA / 7.5KW 60HZ 120VDC 1Ph In/Out less Bat
5196-375 WOB
7.50 KVA / 7.5KW 50HZ 120VDC 1Ph In/Out with Bat
5195-375
LT1075
7.50 KVA / 7.5KW 50HZ 120VDC 1Ph In/Out less Bat
5195-375 WOB
LT1075
10.0 KVA / 8.0KW 60HZ 120VDC 1Ph In/Out with Bat
5196-709A
10.0 KVA / 8.0KW 60HZ 120VDC 1Ph In/Out less Bat
5196-709A WOB
10.0 KVA / 8.0KW 50HZ 120VDC 1Ph In/Out with Bat
5195-709A
LT1080
10.0 KVA / 8.0KW 50HZ 120VDC 1Ph In/Out less Bat
5195-709A WOB
LT1080
Top of Page
Series 1000 Single Phase Family of UPS from 12.5 to 15KVA using a 360VDC Battery Link and consisting of 16 standard configurations.
No Uninterruptible Power Supply delivers cleaner output power than the LTI Power Systems Series 1000. Total input to output Isolation. LTI Power Systems Double Conversion, On-Line UPS converts the contaminated incoming power into a regulated and filtered direct current (DC). The DC charges the batteries and is reconstructed into a new isolated and clean alternating current (AC). This pure AC
is continuously supplied to your critical load, extending its life by providing protection against brownouts, blackouts, and even lightning strikes.

Each model from within the family has a variety of Input and Output voltages and frequencies to choose from as well as internal or external batteries. Other options include: Internal or external wall mounted bypass switch, Separate bypass input, Digital meter panels, Frequency meters, Surge suppression, Alarm extension, and built-in Output Distribution panels.

Description
Part #
Model
12.5 KVA / 10KW 60HZ 360VDC 1Ph In/Out with Bat
5196-709
12.5 KVA / 10KW 60HZ 360VDC 1Ph In/Out less Bat
5196-709 WOB
10.0 KVA / 10KW 50HZ 360VDC 1Ph In/Out with Bat
5195-709
LT1100S
10.0 KVA / 10KW 50HZ 360VDC 1Ph In/Out less Bat
5195-709 WOB
LT1100S
12.5 KVA / 10KW 60HZ 360VDC 3Ph In/1Ph Out with Bat
5196-710
12.5 KVA / 10KW 60HZ 360VDC 3Ph In/1Ph Out less Bat
5196-710 WOB
10.0 KVA / 10KW 50HZ 360VDC 3Ph In/1Ph Out with Bat
5195-710
LT1100
10.0 KVA / 10KW 50HZ 360VDC 3Ph In/1Ph Out less Bat
5195-710 WOB
LT1100
18.75 KVA / 15KW 60HZ 360VDC 1Ph In/Out with Bat
5196-714
18.75 KVA / 15KW 60HZ 360VDC 1Ph In/Out less Bat
5196-714 WOB
15.0 KVA / 15KW 50HZ 360VDC 1Ph In/Out with Bat
5195-714
LT1150S
15.0 KVA / 15KW 50HZ 360VDC 1Ph In/Out less Bat
5195-714 WOB
LT1150S
18.75 KVA / 15KW 60HZ 360VDC 3Ph In/1Ph Out with Bat
5196-715
18.75 KVA / 15KW 60HZ 360VDC 3Ph In/1Ph Out less Bat
5196-715 WOB
15.0 KVA / 15KW 50HZ 360VDC 3Ph In/1Ph Out with Bat
5195-715
LT1150
15.0 KVA / 15KW 50HZ 360VDC 3Ph In/1Ph Out less Bat
5195-715 WOB
LT1150
Series 1000 UPS with or without Internal Battery
Top of Page
Series 1000 Harsh Environment Single Phase Family of UPS from 3.75 to 6 KVA using a 120VDC Battery Link and consisting of 4 standard configurations.
No Uninterruptible Power Supply delivers cleaner output power than the LTI Power Systems Series 1000. Total input to output Isolation. LTI Power Systems Double Conversion, On-Line UPS converts the contaminated incoming power into a regulated and filtered direct current (DC). The DC charges the batteries and is reconstructed into a new isolated and clean alternating current (AC). This pure AC is continuously supplied to your critical load, extending its life by providing protection against brownouts, blackouts, and even lightning strikes.

The Harsh Series provides a wider AC input range from 480 to 120 VAC, a bit wider cabinet with reusable, washable air filters, and is designed for up to a 50º C. continuous operating environment.

Each model from within the family has a variety of Input (from 480VAC) and Output voltages and frequencies to choose from as well as internal or external batteries. Other options include: External wall mounted bypass switch, Separate bypass input, Digital meter panel, Frequency meter, Surge suppression and Alarm extension.
Description
Part #
Model
3.75 KVA / 3.0 KW 60HZ 120VDC 1Ph In/Out with Bat at 40 Deg C
5196-331
6.25 KVA / 5.0 KW 60HZ 120VDC 1Ph In/Out with Bat at 40 Deg C
5196-351
3.00 KVA / 2.4 KW 60HZ 120VDC 1Ph In/Out with Bat at 50 Deg C
5196-331
5.00 KVA / 4.0 KW 60HZ 120VDC 1Ph In/Out with Bat at 50 Deg C
5196-351
Top of Page
Harsh Environment UPS with or without Internal Battery
Series 1000 Single Phase Family of Relay Rack Mounted UPS from 3 to 7.5 KVA using a 120VDC Battery Link and consisting of 6 standard configurations.
Our rack mounted UPS provides clean, uninterruptible AC Power to loads such as; central phone systems, computers, test equipment, alarm monitors, and other critical AC powered devices. The space saving rack mount inverter design is well suited for sensitive telecommunication and data processing installations. The robust inverter can also power more demanding loads such as motors, rectifiers, switch mode power supplies and nonlinear loads.

The UPS is a highly efficient and cost-effective solution for your power problems. Our continuous On-Line UPS design insures maximum critical load protection. The attractive NEMA1 enclosure mounts easily into a standard 19” or 23” rack or may be floor mounted.

Each model from within the family has a variety of Input and Output voltages and frequencies to choose from. Other options include: External rack or wall mounted bypass switch, Separate bypass input, Digital meter panels, Frequency meters, Surge suppression and Alarm extension.
Description
Part #
Model
3.0 KVA / 3.0 KW 60HZ 120VDC 1Ph Out less Bat
5196-333
3.0 KVA / 3.0 KW 50HZ 120VDC 1Ph Out less Bat
5195-333
LT1030RM
5.0 KVA / 5.0 KW 60HZ 120VDC 1Ph Out less Bat
5196-353
5.0 KVA / 5.0 KW 50HZ 120VDC 1Ph Out less Bat
5195-353
LT1050RM
7.5 KVA / 7.5 KW 60HZ 120VDC 1Ph Out less Bat
5196-373
7.5 KVA / 7.5 KW 50HZ 120VDC 1Ph Out less Bat
5195-373
LT1075RM
Top of Page
Rack Mount UPS 3 - 7.5 KVA
Series 1000 Single Phase Family of Relay Rack Mounted Inverters from 1 to 2.5 KW using a 24VDC Battery Link and consisting of 8 standard configurations.
Inverters provides clean, uninterruptible AC Power to loads such as; central phone systems, computers, test equipment, alarm monitors, and other critical AC powered devices. The space saving rack mount inverter design is well suited for sensitive telecommunication and data processing installations. The robust inverter can also power more demanding loads such as motors, rectifiers, switch mode power supplies and nonlinear loads.

The inverter is a highly efficient and cost-effective solution for your power problems. Our continuous On-Line inverter design insures maximum critical load protection. The attractive NEMA1 enclosure mounts easily into a standard 19” or 23” rack or may be floor mounted.

Each model from within the family has a variety of Input and Output voltages and frequencies to choose from and designed for use with external batteries. Other options include: External rack or wall mounted bypass switch, Separate bypass input, Digital meter panels, Frequency meters, Surge suppression, and Alarm extension.
Description
Part #
Model
1.0 KVA / 1.0 KW 60HZ 24VDC 1Ph Out less Bat
5194-010
1.0 KVA / 1.0 KW 50HZ 24VDC 1Ph Out less Bat
5195-010
D102CAA
1.5 KVA / 1.5 KW 60HZ 24VDC 1Ph Out less Bat
5194-015
1.5 KVA / 1.5 KW 60HZ 24VDC 1Ph Out less Bat
5195-015
D152CAA
2.0 KVA / 2.0 KW 60HZ 24VDC 1Ph Out less Bat
5194-020
2.0 KVA / 2.0 KW 50HZ 24VDC 1Ph Out less Bat
5195-020
D202CAA
2.5 KVA / 2.5 KW 60HZ 24VDC 1Ph Out less Bat
5194-025
2.5 KVA / 2.5 KW 50HZ 24VDC 1Ph Out less Bat
5195-025
D252CAA
Rack Mount Inverter 1 - 2.5 KVA
Top of Page
Series 1000 Single Phase Family of Relay Rack Mounted Inverters from 2 to 10 KW using a 48VDC Battery Link
Reliable and versatile... Inverters provides clean, uninterruptible AC Power to loads such as; central phone systems, computers, test equipment, alarm monitors, and other critical AC powered devices. The space saving rack mount inverter design is well suited for sensitive telecommunication and data processing installations. The robust inverter can also power more demanding loads such as motors, rectifiers, switch mode power supplies and nonlinear loads.

The inverter is a highly efficient and cost-effective solution for your power problems. Our continuous On-Line inverter design insures maximum critical load protection. The attractive NEMA1 enclosure mounts easily into a standard 19” or 23” rack or may be floor mounted.

Each model from within the family has a variety of Input and Output voltages and frequencies to choose from and designed for use with external batteries. Other options include: External rack or wall mounted bypass switch, Separate bypass input, Digital meter panels, Frequency meters, Surge suppression, and Alarm extension.
Description
Part #
Model
2.0 KVA / 2.0 KW 60HZ 48VDC 1Ph Out less Bat
5196-020
2.0 KVA / 2.0 KW 50HZ 48VDC 1Ph Out less Bat
5195-020
D202CYB
3.0 KVA / 3.0 KW 60HZ 48VDC 1Ph Out less Bat
5196-030
3.0 KVA / 3.0 KW 50HZ 48VDC 1Ph Out less Bat
5195-030
D302CYB
5.0 KVA / 5.0 KW 60HZ 48VDC 1Ph Out less Bat
5196-050
5.0 KVA / 5.0 KW 50HZ 48VDC 1Ph Out less Bat
5195-050
D502CYB
10 KVA / 10 KW 60HZ 48VDC 1Ph Out less Bat
5196-110
10 KVA / 10 KW 50HZ 48VDC 1Ph Out less Bat
5195-110
D103CYB
Rack Mount Inverter 2 - 5 KVA
Top of Page
Series 1000 Single Phase Family of Relay Rack Mounted Inverters from 3 to 8 KVA using a 120VDC Battery Link and consisting of 8 standard configurations.
The reliable and versatile Inverters from LTI provide clean, uninterruptible AC Power to loads such as; central phone systems, computers, test equipment, alarm monitors, and other critical AC powered devices. The space saving rack mount inverter design is well suited for sensitive telecommunication and data processing installations. The robust inverters can also power more demanding loads such as motors, rectifiers, switch mode power supplies and nonlinear loads.

The inverter is a highly efficient and cost-effective solution for your power problems. Our continuous On-Line inverter design insures maximum critical load protection. The attractive NEMA1 enclosure mounts easily into a standard 19” or 23” rack or may be floor mounted.

Each model from within the family has a variety of Input and Output voltages and frequencies to choose from and designed for use with external batteries. Other options include: External rack or wall mounted bypass switch, Separate bypass input, Digital meter panels, Frequency meters, Surge suppression, and Alarm extension.
Description
Part #
Model
3.00 KVA / 3.0 KW 60HZ 120VDC 1Ph Out less Bat
5196-103
D302CAHRM
3.00 KVA / 3.0 KW 50HZ 120VDC 1Ph Out less Bat
5195-XXX
5.00 KVA / 5.0 KW 60HZ 120VDC 1Ph Out less Bat
5196-105
5.00 KVA / 5.0 KW 50HZ 120VDC 1Ph Out less Bat
5195-XXX
7.50 KVA / 7.5 KW 60HZ 120VDC 1Ph Out less Bat
5196-107
7.50 KVA / 7.5 KW 50HZ 120VDC 1Ph Out less Bat
5195-XXX
8.00 KVA / 8.0 KW 60HZ 120VDC 1Ph Out less Bat
5196-108
8.00 KVA / 8.0 KW 60HZ 120VDC 1Ph Out less Bat
5195-XXX
Rack Mount Inverter 3 - 8 KVA
Top of Page
Series 500 Single Phase Family of Desk Top / Floor / Rack Mounted UPS starting with 1500VA, using a 48VDC Internal Battery to provide 7 minutes reserve at full load and 18 minutes at half load.
In today’s world where power requirements are increasing, the quality of utility power and reliability are decreasing. Normal everyday routines are constantly exposed to power problems such as Surges, Brownouts and Power Outages. Any of these problems can spell disaster for the unprepared. Down time resulting in loss of data and equipment damage from power problems costs industries as well as the private sector millions of dollars over the course of a year.

One way to protect sensitive equipment from Surges, Brownouts and Power Outages is LTI’s LT500 Series of true 0n-line UPS’s.

Designed for optimizing power quality with ease of installation, the LT Series features:

Double Conversion.

Continuously Operating Battery Charger and Inverter.

Constant Battery Connection to the Inverter and load.

One Internal Battery Pack Included.

Guaranteed full power operation for 7 Min or 18 Min at half load during power failure.

Zero Transfer Time.

Light Weight.

Hot-Swappable Battery.

User-Friendly Graphics LCD.

Flexible Mounting Orientation with Rotatable LCD Design.

Series 500 UPS with Rotating Display
APPLICATIONS INCLUDE:

Computers Network Servers Workstations Wireless Communications Other Electronic Peripherals

Complete software monitoring and control provides the user with the ability to customize the following settings:

UPS, Software, Messaging, E-mail, Pager and the Toolbar.

Description
Part #
Model
1500VA at .8 PF / 1050W 60HZ 120VAC 1Ph In/Out with Bat ( 7-18 Min)
9135-1500
Top of Page
Static Transfer Switch Wall or Relay Rack Mounted from 20 to 100A for use with 120VAC and consisting of 9 standard configurations.

The LTI static switch will provide virtually uninterruptible power to any critical load by automatically or manually selecting between one of two AC input sources. If the preferred source deviates outside preset limits the unit will instantaneously transfer to the secondary sources. Upon return of the preferred source to within acceptable limits, the static switch will automatically transfer the load back . This insures that the sensitive load is always being supplied the best available power from two sources.
Rack Mounted Static Switch
Description
Part #
Model
20 Amp 1 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-505
20 Amp 2 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-510
30 Amp 1 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-XXX
30 Amp 2 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-XXX
LTSS30-2
40 Amp 1 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-XXX
LTSS40-1
40 Amp 2 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-XXX
LTSS40-2
50 Amp 1 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-550
50 Amp 2 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-XXX
LTSS50-2
100 Amp 1 Pole Static Switch 120VAC 1PH 60 HZ 2 Wire plus Gnd
4866-580
Top of Page

Providing Uninterruptible Power for:

Industrial - Petrochemical - Communications - Emergency Services - Utilities - Banks - Data Centers - Hospitals - Phone Systems - Chemical Processes - Computers - Pulp and Paper - Tire - Glass - Textile - Distributive Central Systems - Lighting - Automotive Manufacturing - Oil and Gas Pipeline Controls - Pharmaceutical Manufacturing - and more…

All text and images © Copyright 2004 LTI Power Systems
All Rights Reserved
Website Design: David Nieding